top of page

ENGO 230v Wiring Centre
ECB08M230 control box is the main element of the underfloor heating control sys-
tem. It has a buil- box. It-in modules that controls the heat sources (by volt-free relay)
and pump (230V AC). The control box allows to control 8 different zones. It is equip-
ped with 230V AC voltage outputs for actuators. Pluggable terminal blocks provide
quick and convenient wiring connections. The control box is designed to work with
NC (normally-closed) type actuators.
tem. It has a buil- box. It-in modules that controls the heat sources (by volt-free relay)
and pump (230V AC). The control box allows to control 8 different zones. It is equip-
ped with 230V AC voltage outputs for actuators. Pluggable terminal blocks provide
quick and convenient wiring connections. The control box is designed to work with
NC (normally-closed) type actuators.

ENGO Wireless Wiring Centre
Control box allows to controlthe surface heating. Itis equipped with voltage out-
puts 230V forthe circulation pump,thermostats and thermoelectric actuators.
The control box allows control of 8 heating zones in a combination of connec-
tions – 2 wired and 6 wireless temperature thermostats. It works with NC type
actuators, such as E30NC230, E28NC230. The control box has a built-in module
for controlling a heating device, e.g. boiler, heat pump (voltage-free output).
Wired control is performed by direct cable connection of thermostats to the con-
trol box. The thermostats can be battery operated (COM-NO contact) or powered
by 230V AC. Wireless communication is performed in ZigBee 3.0 technology with
dedicated temperature thermostats EONEBAT, EONE230 via EGATZB Internet
gateway. In addition, by connecting the EGATZB gateway to the Internet, it is
possible to control room temperature* using the free ENGO Smart/TUYA Smart
mobile application.
puts 230V forthe circulation pump,thermostats and thermoelectric actuators.
The control box allows control of 8 heating zones in a combination of connec-
tions – 2 wired and 6 wireless temperature thermostats. It works with NC type
actuators, such as E30NC230, E28NC230. The control box has a built-in module
for controlling a heating device, e.g. boiler, heat pump (voltage-free output).
Wired control is performed by direct cable connection of thermostats to the con-
trol box. The thermostats can be battery operated (COM-NO contact) or powered
by 230V AC. Wireless communication is performed in ZigBee 3.0 technology with
dedicated temperature thermostats EONEBAT, EONE230 via EGATZB Internet
gateway. In addition, by connecting the EGATZB gateway to the Internet, it is
possible to control room temperature* using the free ENGO Smart/TUYA Smart
mobile application.

Heatmiser UH4 4 Zone Wiring Centre
The UH4 is an 4 Zone & Hot water wiring centre for use with Heatmiser
230v thermostats.
The UH4 can be used to control any actuator or valve which requires a
230v AC signal. At the same time the UH4 offers the ability to operate a
boiler or other heat source through a volt free output.
An additional output designed for use with underfloor heating
systems, is also included as standard. This is the pump/valve Output,
which would normally operate a manifold pump or a manifold valve.
The H/W output provides a 230v hot water enable signal to the valve,
the auxiliary wires of the valve are wired to the Gr & Or terminals.
Zone 4 can be used as an isolated radiator zone by using the
Yes/No switch.
If the switch is set to NO;
When zone 4 calls for heat this will provide an output to a radiator
zone valve and the boiler but WILL NOT enable the underfloor heating
pump/valve output.
If the switch is set to YES;
When Zone 4 calls for heat, this will act as an underfloor heating zone,
by enabling the actuator, boiler and pump/valve outputs.
Any output which is not needed can be ignored.
230v thermostats.
The UH4 can be used to control any actuator or valve which requires a
230v AC signal. At the same time the UH4 offers the ability to operate a
boiler or other heat source through a volt free output.
An additional output designed for use with underfloor heating
systems, is also included as standard. This is the pump/valve Output,
which would normally operate a manifold pump or a manifold valve.
The H/W output provides a 230v hot water enable signal to the valve,
the auxiliary wires of the valve are wired to the Gr & Or terminals.
Zone 4 can be used as an isolated radiator zone by using the
Yes/No switch.
If the switch is set to NO;
When zone 4 calls for heat this will provide an output to a radiator
zone valve and the boiler but WILL NOT enable the underfloor heating
pump/valve output.
If the switch is set to YES;
When Zone 4 calls for heat, this will act as an underfloor heating zone,
by enabling the actuator, boiler and pump/valve outputs.
Any output which is not needed can be ignored.

Heatmiser UH8 8 Zone Wiring Centre
The UH8 is an 8 Zone wiring centre for use with Heatmiser
230v thermostats.
The UH8 can be used to control any actuator or valve which requires
a 230v AC signal to open. For mid position valves and those requiring
a closing signal, a changeover relay is required. At the same time the
UH8 offers the ability to operate a boiler or other heat source through
a volt free output.
Additional outputs designed for use with underfloor heating systems
are also included as standard. These are the pump and valve outputs
which would normally operate a manifold pump or a manifold valve.
Zone 8 can be used as an isolated radiator zone by using the
UFH/RAD switch.
If the switch is set to RAD;
When zone 8 calls for heat this will provide an output to a radiator
zone valve and the boiler, but WILL NOT enable the underfloor
heating pump/valve output.
If the switch is set to UFH;
When Zone 8 calls for heat, this will act as an underfloor heating zone,
by enabling the actuator, boiler and pump/valve outputs.
Any output which is not needed can be ignored.
230v thermostats.
The UH8 can be used to control any actuator or valve which requires
a 230v AC signal to open. For mid position valves and those requiring
a closing signal, a changeover relay is required. At the same time the
UH8 offers the ability to operate a boiler or other heat source through
a volt free output.
Additional outputs designed for use with underfloor heating systems
are also included as standard. These are the pump and valve outputs
which would normally operate a manifold pump or a manifold valve.
Zone 8 can be used as an isolated radiator zone by using the
UFH/RAD switch.
If the switch is set to RAD;
When zone 8 calls for heat this will provide an output to a radiator
zone valve and the boiler, but WILL NOT enable the underfloor
heating pump/valve output.
If the switch is set to UFH;
When Zone 8 calls for heat, this will act as an underfloor heating zone,
by enabling the actuator, boiler and pump/valve outputs.
Any output which is not needed can be ignored.

Heatmiser UH8-RF Wireless Wiring Centre
The UH8-RF V2 is an 8 Zone central wiring centre for use with
Heatmiser RF thermostats.
The UH8-RF V2 can be used to control any actuator or valve, which
requires a 230v AC signal to open. For mid position valves and those
requiring a closing signal, a changeover relay is required. The
UH8-RF V2 also offers the ability to operate a boiler or other heat
source through a volt free output with changeover contacts, giving
you both a heat on signal and a heat off signal.
Additional outputs designed for use with hot water or underfloor
heating systems, are also included as standard. These are the pump
and valve outputs which would normally operate a manifold pump
or a manifold valve.
Any output which is not needed can be ignored.
When wiring directly to the heat source is not possible, a radio link is
provided to remotely enable a separate receiver, the RF-Switch.
Test switches are included for the installation engineer and further
options include creepage protection and pump delay.
Heatmiser RF thermostats.
The UH8-RF V2 can be used to control any actuator or valve, which
requires a 230v AC signal to open. For mid position valves and those
requiring a closing signal, a changeover relay is required. The
UH8-RF V2 also offers the ability to operate a boiler or other heat
source through a volt free output with changeover contacts, giving
you both a heat on signal and a heat off signal.
Additional outputs designed for use with hot water or underfloor
heating systems, are also included as standard. These are the pump
and valve outputs which would normally operate a manifold pump
or a manifold valve.
Any output which is not needed can be ignored.
When wiring directly to the heat source is not possible, a radio link is
provided to remotely enable a separate receiver, the RF-Switch.
Test switches are included for the installation engineer and further
options include creepage protection and pump delay.

SALUS 8 Zone 230v Wiring Centre
The KL08RF wireless wiring centre is a part of the iT600RF system. In combination with the wireless thermostats
from iT600RF series, KL08RF provides comfortable and reliable heating control. It is equipped with the control
outputs for the pump and boiler and has been designed to work with NC or NO actuators.
In Offline mode, communication with the wireless thermostats from iT600RF series must be done through
the CO10RF co-ordinating unit, which is in the package together with the wiring centre. To work in Online mode
(via the SALUS Smart Home app) KL08RF must be connected to the Internet gateway UGE600. In one ZigBee
network (Online or Offline) up to 9 KL08RF wiring centres can be connected. KL08RF increases ZigBee network
range.
from iT600RF series, KL08RF provides comfortable and reliable heating control. It is equipped with the control
outputs for the pump and boiler and has been designed to work with NC or NO actuators.
In Offline mode, communication with the wireless thermostats from iT600RF series must be done through
the CO10RF co-ordinating unit, which is in the package together with the wiring centre. To work in Online mode
(via the SALUS Smart Home app) KL08RF must be connected to the Internet gateway UGE600. In one ZigBee
network (Online or Offline) up to 9 KL08RF wiring centres can be connected. KL08RF increases ZigBee network
range.

SALUS 8 Zone Wireless Wiring Centre
The CB500 control box is the main element of the underfloor heating / cooling control system.
It has a built-in module that controls the heat and cool sources. The control box allows you
to control 5 different zones. Number of controlled zones can be increased up to 15 zones by
using additional CB500X extension modules (CB500 main control box + two CB500X extension
modules). Each individual zone can be operated by one thermostat. Thermostat which require
230V power supply have to be powered directly from control box. The CB500 has voltage-free
outputs designed to control a boiler, heat pump or chiller. It allows you to switch between
heating and cooling modes. It is equipped with 230V voltage outputs for a pump and
actuators. The spring clamps provide quick and convenient wiring connections. The control box
is designed to work with NC (normally-closed) type actuators. It is recommended to mount it
on a surface or on a DIN rail.
It has a built-in module that controls the heat and cool sources. The control box allows you
to control 5 different zones. Number of controlled zones can be increased up to 15 zones by
using additional CB500X extension modules (CB500 main control box + two CB500X extension
modules). Each individual zone can be operated by one thermostat. Thermostat which require
230V power supply have to be powered directly from control box. The CB500 has voltage-free
outputs designed to control a boiler, heat pump or chiller. It allows you to switch between
heating and cooling modes. It is equipped with 230V voltage outputs for a pump and
actuators. The spring clamps provide quick and convenient wiring connections. The control box
is designed to work with NC (normally-closed) type actuators. It is recommended to mount it
on a surface or on a DIN rail.
WIRING CENTRE
bottom of page